Specs
Training Day specs
Training notes and checklist items for Training Day.
How Training Day specs support handover
The Training Day specs page sets out what is covered during operator training for a genset on site. It includes the points that become important once the team has moved past the first easy run and starts dealing with real operating conditions.
Training Day specs focus on what operators must check before, during and after a site run. The handover covers control panel indications, breaker positions, emergency stop location, fuel level checks and basic fault responses on installed gensets. Conditions such as Highveld dust, coastal corrosion and frequent load shedding are included where they affect daily operation.
Each session should start with the installed unit, not a generic manual. Photos of the controller, changeover panel, battery isolator and drain points help the team match the checklist to the exact machine on site. That record is useful when shift staff rotate and the next test run needs to follow the same sequence.
Operator handover on site
The Training Day pack sets out startup order, shutdown order and the checks to log after a loaded run. It also notes which alarms need escalation and which items can be confirmed by visual inspection at the canopy or control panel. For sites with an ATS, the handover includes mains failure simulation and return-to-mains observation.
Use these Training Day specs alongside runtime notes and the site load record before changing operating routines. Confirm the ATS panel label, controller model and current breaker arrangement against the installed set, then send updates through the contact form. That keeps the training sheet aligned with the machine the team will actually operate.
- Startup sequence for the installed genset
- Alarm checks recorded during test run
- Site checklist for operators and supervisors
Load shedding handover points
Training must reflect how South African sites actually run during outages. That means covering manual changeover where fitted, generator checks after repeated starts, and refuelling controls when a shift spans more than one outage window. Plants near Johannesburg may prioritise dust and intake inspection, while Durban and Cape Town sites may need closer attention to corrosion and enclosure seals.
The handover should include weekly exercise runs, coolant and oil level checks, and battery charger confirmation before an outage occurs. Where the genset serves a factory, warehouse or retail site, staff also need to know which loads must stay off during startup to avoid unnecessary trips. Runtime logging matters because service intervals are tied to actual operating hours, not only the calendar.
Operated by Astros Marketing (Pty) Ltd from 2 Makro Place, Sunnyrock 1401.
Checklist items covered in training
Use Training Day when operators, maintenance staff or site supervisors need practical handover on generator checks and changeover basics.
Training Day specs should list the controller readings to observe, the switch positions to verify and the shutdown checks required after the run. Include space for the ATS reference, engine hours, service contact details and any site-specific cautions noted during handover. This gives maintenance staff and supervisors a usable record for later testing and audits.